AS 5194/95 - Living unit station for charging floor heating systems

Description of Unit

The AS 5194/AS 5195 are charging controllers (living unit stations) which make use of the most up-to-date technology. The AS 5194 handles as many as 4 separate heating circuits of a thermal storage floor heating system and determines the charging of each individual circuit as a function of the reference input value formed by central station 5190. The AS 5195 does the same for a maximum 2 separate heating circuits.

Example of use

 

 

Dimensions 105 x 90 x 50 mm
Power requirement approx. 2,5 VA
rated voltage 230 V / 50 Hz
SH- breaking capacity 230 V, Taktsignal 1,5 A Charakteristik 80%
Terminal 3 SH1 250 V ~ / 6 A
Terminal 5 SH2 250 V ~ / 6 A
with AS 5194 additional  
*Terminal 6 SH3 250 V ~ / 3 A
*Terminal 8 SH4 250 V ~ / 3 A
Permissible ambient temperature 0°C bis +50°C
Mounting top hat rail 35 x 7,5 in compliance with DIN 50022
Load characteristic Split-/forward-/backward control