AS 511 - Charging controller

Description of Unit

 

The AS 511 is a charging control which employs the most up-to-date

microcomputer technology. The automatic charging device AS 511

determines the charging rate for electrical thermal storage heaters

based on outside temperature and residual heat. It is suited for

driving thermal storage heaters with thermomechanical charging

controllers (heatable liquid bulb thermostats, capillary sensors,

thermal contactors).

For group controlling the AS 597 is recommended. Detailed describtion of AS597 find by clicking "back" and "AS 597".

 

Load characteristic

Example of use

 

 

Dimensions 53 x 90 x 53 mm
Power requirement approx. 2,2 VA + A1-breaking capacity
Control voltage A1 230 V clock signal 1,5A -80% on-period
rated voltage 230 V / 50 Hz
Load characteristic Split - forward / backward control
Permissible ambient temperature 0°C to +50°
Mounting top hat rail 35 x 7,5 DIN 50 022 without wall mounting